Daikin VRV X System Price in Mumbai | BeCool AC
Daikin Authorized Dealer Daikin VRV X
VRV Air Conditioner R410A Refrigerant

Daikin VRV X

VRV Air Conditioner — Mumbai

First launched in Japan in 1982, the Daikin VRV X system has been embraced by the world markets for over three decades. Now, Daikin introduces the next generation VRV X system to reinforce its industry leadership. The system now offers an enhanced line-up to meet an ever widening variety of needs, while improving energy savings, comfort and ease of installation.

The VRV X is the most advanced airconditioning system in the world and is ideal for large and small spaces.

VRT – Variable Refrigerant Temperature in Indoor Unit (IDU) and Outdoor Unit (ODU).

  • Product CategoryVRV Air Conditioner VRV X
  • ModelVRV X
Get Best Price *Installation extra.

Salient Features

  • Lower Operation Sound
  • Next-Gen Compressor & VRT Smart Control
  • Reliable & Stable System
  • Up to 60HP

Specification — Cooling Only: RXQ6ARY6/8ARY6/10ARY6/12ARY6/14ARY6/16ARY6

ModelRXQ6ARY6RXQ8ARY6RXQ10ARY6RXQ12ARY6RXQ14ARY6RXQ16ARY6
Power Supply3-Phase, 380-415V, 50Hz
Cooling Capacity (Btu/h)54,60076,40095,5001,14,0001,36,0001,54,000
Cooling Capacity (kW)1622.42833.54045
Capacity Control (%)25~10020~10013~10012~10011~10010~100
Casing ColourIvory White (5Y7.5/1)
Compressor TypeHermetically Sealed Scroll Type
No. of Compressor111112
Airflow Rate (m³/min)119178191257
Dimensions H×W×D (mm)1,657×930×7651,657×1,240×765
Machine Weight (kg)165175220260
Sound Level (dBA)565657596060
Operation Range – Cooling (°CDB)10 ~ 49
Refrigerant TypeR410A
Refrigerant Charge (kg)5.96.76.87.48.2
Liquid Pipe (mm)ø9.5ø12.7
Gas Pipe (mm)ø19.1ø22.2ø28.6

Note

Specifications are based on the following conditions:

1. Cooling – Indoor temp. 27°CDB, 19°CWB, Outdoor temp. 35°CDB, Equivalent piping length 7.5m, Level difference 0m.

2. Sound level – Anechoic chamber conversion value, measured at a point 1m in front of the unit at a height of 1.5m; during actual operation these values are normally somewhat higher as a result of ambient conditions.

Specification — Cooling Only: RXQ18ARY6/20ARY6/22ARY6/24ARY6

ModelRXQ18ARY6RXQ20ARY6RXQ22ARY6RXQ24ARY6
Combination UnitsRXQ10ARY6 + RXQ12ARY6RXQ12ARY6 + RXQ12ARY6
Power Supply3-Phase, 380-415V, 50Hz
Cooling Capacity (Btu/h)1,71,0001,91,0002,10,0002,29,000
Cooling Capacity (kW)50.056.061.567.0
Capacity Control (%)10~1007~1006~100
Casing ColourIvory White (5Y7.5/1)
Compressor TypeHermetically Sealed Scroll Type
No. of Compressor221+11+1
Airflow Rate (m³/min)257297178+191191+191
Dimensions H×W×D (mm)1,657×1,240×765(1,657×930×765)+(1,657×930×765)
Machine Weight (kg)260285175+175
Sound Level (dBA)61656162
Operation Range – Cooling (°CDB)10 ~ 49
Refrigerant TypeR410A
Refrigerant Charge (kg)8.411.86.7+6.86.8+6.8
Liquid Pipe (mm)ø15.9
Gas Pipe (mm)ø28.6ø34.9

Note

Specifications are based on the following conditions:

1. Cooling – Indoor temp. 27°CDB, 19°CWB, Outdoor temp. 35°CDB, Equivalent piping length 7.5m, Level difference 0m.

2. Sound level – Anechoic chamber conversion value, measured at a point 1m in front of the unit at a height of 1.5m; during actual operation these values are normally somewhat higher as a result of ambient conditions.

Specification — Cooling Only: RXQ26ARY6/28ARY6/30ARY6/32ARY6/34ARY6/36ARY6

ModelRXQ26ARY6RXQ28ARY6RXQ30ARY6RXQ32ARY6RXQ34ARY6RXQ36ARY6
Power Supply3-Phase, 380-415V, 50Hz
Cooling Capacity (Btu/h)2,47,0002,68,0002,85,0003,05,0003,24,0003,41,000
Cooling Capacity (kW)73.578.583.59095100
Capacity Control (%)6~1005~1005~1005~1004~1005~100
Casing ColourIvory White (5Y7.5/1)
Compressor TypeHermetically Sealed Scroll Type
No. of Compressor1+11+21+21+22+22+2
Airflow Rate (m³/min)191+257257+257257+257
Dimensions H×W×D (mm)(1,657×930×765)+(1,657×1,240×765)(1,657×1,240×765)+(1,657×1,240×765)
Machine Weight (kg)175+220175+260220+260260+260
Sound Level (dBA)6364
Operation Range – Cooling (°CDB)10 ~ 49
Refrigerant TypeR410A
Refrigerant Charge (kg)6.8+7.46.8+8.26.8+8.47.4+8.48.2+8.48.4+8.4
Liquid Pipe (mm)ø19.1
Gas Pipe (mm)ø34.9ø41.3

Note

Specifications are based on the following conditions:

1. Cooling – Indoor temp. 27°CDB, 19°CWB, Outdoor temp. 35°CDB, Equivalent piping length 7.5m, Level difference 0m.

2. Sound level – Anechoic chamber conversion value, measured at a point 1m in front of the unit at a height of 1.5m; during actual operation these values are normally somewhat higher as a result of ambient conditions.

Specification — Cooling Only: RXQ38ARY6/40ARY6/42ARY6/44ARY6/46ARY6/48ARY6/50ARY6

ModelRXQ38ARY6RXQ40ARY6RXQ42ARY6RXQ44ARY6RXQ46ARY6RXQ48ARY6RXQ50ARY6
Power Supply3-Phase, 380-415V, 50Hz
Cooling Capacity (Btu/h)3,62,0003,82,0003,99,0004,20,0004,40,0004,57,0004,78,000
Cooling Capacity (kW)106112117123129134140
Capacity Control (%)4~1003~1004~1003~100
Casing ColourIvory White (5Y7.5/1)
Compressor TypeHermetically Sealed Scroll Type
No. of Compressor2+21+1+21+2+2
Airflow Rate (m³/min)257+297297+297191+191+257 / 191+191+297257+257+257
Machine Weight (kg)260+285285+285175+175+260175+175+285220+220+260220+260+260220+260+260
Sound Level (dBA)6668656765
Operation Range – Cooling (°CDB)10 ~ 49
Refrigerant TypeR410A
Refrigerant Charge (kg)8.4+11.811.8+11.86.8+6.8+8.46.8+6.8+11.87.4+7.4+11.87.4+8.2+8.47.4+8.4+8.4
Liquid Pipe (mm)ø19.1
Gas Pipe (mm)ø41.3

Note

Specifications are based on the following conditions:

1. Cooling – Indoor temp. 27°CDB, 19°CWB, Outdoor temp. 35°CDB, Equivalent piping length 7.5m, Level difference 0m.

2. Sound level – Anechoic chamber conversion value, measured at a point 1m in front of the unit at a height of 1.5m; during actual operation these values are normally somewhat higher as a result of ambient conditions.

Specification — Cooling Only: RXQ52ARY6/54ARY6/56ARY6/58ARY6/60ARY6

ModelRXQ52ARY6RXQ54ARY6RXQ56ARY6RXQ58ARY6RXQ60ARY6
Power Supply3-Phase, 380-415V, 50Hz
Cooling Capacity (Btu/h)4,95,0005,12,0005,32,0005,53,0005,73,000
Cooling Capacity (kW)145150156162168
Capacity Control (%)3~1002~100
Casing ColourIvory White (5Y7.5/1)
Compressor TypeHermetically Sealed Scroll Type
No. of Compressor2+2+2
Airflow Rate (m³/min)257+257+257257+297+297
Machine Weight (kg)260+260+260260+260+285260+285+285285+285+285
Sound Level (dBA)6566686970
Operation Range – Cooling (°CDB)10 ~ 49
Refrigerant TypeR410A
Refrigerant Charge (kg)8.2+8.4+8.48.4+8.4+8.48.4+8.4+11.88.4+11.8+11.811.8+11.8+11.8
Liquid Pipe (mm)ø19.1
Gas Pipe (mm)ø41.3

Note

Specifications are based on the following conditions:

1. Cooling – Indoor temp. 27°CDB, 19°CWB, Outdoor temp. 35°CDB, Equivalent piping length 7.5m, Level difference 0m.

2. Sound level – Anechoic chamber conversion value, measured at a point 1m in front of the unit at a height of 1.5m; during actual operation these values are normally somewhat higher as a result of ambient conditions.

Specification — Cooling Only: RXQ215ARY6B / RXQ430ARY6B / RXQ645ARY6B (Modular)

ModelRXQ215ARY6BRXQ430ARY6BRXQ645ARY6B
Power Supply3-Phase, 380-415V, 50Hz
Cooling Capacity (Btu/h)2,04,7004,09,4006,14,100
Cooling Capacity (kW)60120180
Power Input – Cooling (kW)19.739.459.1
C.O.P (Cooling)3.05
Capacity Control (%)50-13050-13050-120
Casing ColourIvory White (5Y7.5/1)
Compressor TypeHermetically Sealed Scroll Type
No. of Compressor246
Airflow Rate (m³/min)297594891
Machine Weight (kg)285285+285285+285+285
Sound Level (dBA)656870
Operation Range – Cooling (°CDB)10 ~ 49
Refrigerant TypeR410A
Refrigerant Charge (kg)11.811.8+11.811.8+11.8+11.8
Liquid Pipe (mm)ø15.9 (Brazing)ø19.1 (Brazing)
Gas Pipe (mm)ø26.8 (Brazing)ø41.3 (Brazing)

Specification — Heat Pump: RXYQ6ARY6/8ARY6/10ARY6/12ARY6

ModelRXYQ6ARY6RXYQ8ARY6RXYQ10ARY6RXYQ12ARY6
Power Supply3-Phase, 380-415V, 50Hz
Cooling Capacity (Btu/h)54,60076,40095,5001,14,000
Cooling Capacity (kW)1622.42833.5
Heating Capacity (Btu/h)61,40085,3001,07,0001,28,000
Heating Capacity (kW)182531.537.5
Capacity Control (%)25-10025-10013-10012-100
Casing ColourIvory White (5Y7.5/1)
Compressor TypeHermetically Sealed Scroll Type
No. of Compressor1
Airflow Rate (m³/min)119178191
Dimensions H×W×D (mm)1,657×930×765
Machine Weight (kg)180195
Sound Level (dBA)5657
Operation Range – Cooling (°CDB)-5 ~ 49
Operation Range – Heating (°CDB)-20 ~ 15.5
Refrigerant TypeR410A
Refrigerant Charge (kg)6.97.07.47.6
Liquid Pipe (mm)ø9.5ø12.7
Gas Pipe (mm)ø19.1ø22.2ø28.6

Note

Specifications are based on the following conditions:

1. Cooling – Indoor temp. 27°CDB, 19°CWB, Outdoor temp. 35°CDB, Equivalent piping length 7.5m, Level difference 0m.

2. Heating – Indoor temp. 20°CDB, Outdoor temp. 7°CDB, 6°CWB, Equivalent piping length 7.5m, Level difference 0m.

3. Sound level – Anechoic chamber conversion value, measured at a point 1m in front of the unit at a height of 1.5m; during actual operation these values are normally somewhat higher as a result of ambient conditions.

Specification — Heat Pump: RXYQ14ARY6/16ARY6

ModelRXYQ14ARY6RXYQ16ARY6
Power Supply3-Phase, 380-415V, 50Hz
Cooling Capacity (Btu/h)1,36,0001,54,000
Cooling Capacity (kW)4045
Heating Capacity (Btu/h)1,54,0001,71,000
Heating Capacity (kW)4550
Capacity Control (%)11-10010-100
Casing ColourIvory White (5Y7.5/1)
Compressor TypeHermetically Sealed Scroll Type
No. of Compressor2
Airflow Rate (m³/min)257
Dimensions H×W×D (mm)1,657×1,240×765
Machine Weight (kg)265
Sound Level (dBA)60
Operation Range – Cooling (°CDB)-5 ~ 49
Operation Range – Heating (°CDB)-20 ~ 15.5
Refrigerant TypeR410A
Refrigerant Charge (kg)9.19.3
Liquid Pipe (mm)ø12.7
Gas Pipe (mm)ø28.6

Note

Specifications are based on the following conditions:

1. Cooling – Indoor temp. 27°CDB, 19°CWB, Outdoor temp. 35°CDB, Equivalent piping length 7.5m, Level difference 0m.

2. Heating – Indoor temp. 20°CDB, Outdoor temp. 7°CDB, 6°CWB, Equivalent piping length 7.5m, Level difference 0m.

3. Sound level – Anechoic chamber conversion value, measured at a point 1m in front of the unit at a height of 1.5m; during actual operation these values are normally somewhat higher as a result of ambient conditions.

Specification — Heat Pump: RXYQ18ARY6/20ARY6/22ARY6/24ARY6

ModelRXYQ18ARY6RXYQ20ARY6RXYQ22ARY6RXYQ24ARY6
Combination UnitsRXYQ10ARY6RXYQ12ARY6
RXYQ12ARY6RXYQ12ARY6
Power Supply3-Phase, 380-415V, 50Hz
Cooling Capacity (Btu/h)1,71,0001,91,0002,10,0002,29,000
Cooling Capacity (kW)50.056.061.567.0
Heating Capacity (Btu/h)1,91,0002,15,0002,35,0002,56,000
Heating Capacity (kW)56.063.069.075.0
Capacity Control (%)10-1007-1006-100
Casing ColourIvory White (5Y7.5/1)
Compressor TypeHermetically Sealed Scroll Type
No. of Compressor21+1
Airflow Rate (m³/min)257297178+191191+191
Dimensions H×W×D (mm)1,657×1,240×765(1,657×930×765)+(1,657×930×765)
Machine Weight (kg)285305195+195
Sound Level (dBA)61656162
Operation Range – Cooling (°CDB)-5 ~ 49
Operation Range – Heating (°CDB)-20 ~ 15.5
Refrigerant TypeR410A
Refrigerant Charge (kg)11.87.4+7.67.6+7.6
Liquid Pipe (mm)ø15.9
Gas Pipe (mm)ø28.6ø34.9

Note

Specifications are based on the following conditions:

1. Cooling – Indoor temp. 27°CDB, 19°CWB, Outdoor temp. 35°CDB, Equivalent piping length 7.5m, Level difference 0m.

2. Heating – Indoor temp. 20°CDB, Outdoor temp. 7°CDB, 6°CWB, Equivalent piping length 7.5m, Level difference 0m.

3. Sound level – Anechoic chamber conversion value, measured at a point 1m in front of the unit at a height of 1.5m; during actual operation these values are normally somewhat higher as a result of ambient conditions.

Specification — Heat Pump: RXYQ26ARY6/28ARY6/30ARY6/32ARY6/34ARY6/36ARY6

ModelRXYQ26ARY6RXYQ28ARY6RXYQ30ARY6RXYQ32ARY6RXYQ34ARY6RXYQ36ARY6
Power Supply3-Phase, 380-415V, 50Hz
Cooling Capacity (Btu/h)2,47,0002,68,0002,85,0003,05,0003,24,0003,45,000
Cooling Capacity (kW)73.578.583.590.095.0101.0
Heating Capacity (Btu/h)2,99,0003,19,0003,41,0003,62,0003,86,000
Heating Capacity (kW)82.587.593.5100.0106.0113.0
Capacity Control (%)5-1004-100
Casing ColourIvory White (5Y7.5/1)
Compressor TypeHermetically Sealed Scroll Type
No. of Compressor1+22+2
Airflow Rate (m³/min)191+257257+257257+297
Machine Weight (kg)195+265195+265195+285265+265265+285265+305
Sound Level (dBA)636466
Operation Range – Cooling (°CDB)-5 ~ 49
Operation Range – Heating (°CDB)-20 ~ 15.5
Refrigerant TypeR410A
Refrigerant Charge (kg)7.6+9.17.6+9.37.6+11.89.3+9.39.3+11.8
Liquid Pipe (mm)ø19.1
Gas Pipe (mm)ø34.9ø41.3

Note

Specifications are based on the following conditions:

1. Cooling – Indoor temp. 27°CDB, 19°CWB, Outdoor temp. 35°CDB, Equivalent piping length 7.5m, Level difference 0m.

2. Heating – Indoor temp. 20°CDB, Outdoor temp. 7°CDB, 6°CWB, Equivalent piping length 7.5m, Level difference 0m.

3. Sound level – Anechoic chamber conversion value, measured at a point 1m in front of the unit at a height of 1.5m; during actual operation these values are normally somewhat higher as a result of ambient conditions.

Specification — Heat Pump: RXYQ38ARY6/40ARY6/42ARY6/44ARY6

ModelRXYQ38ARY6RXYQ40ARY6RXYQ42ARY6RXYQ44ARY6
Power Supply3-Phase, 380-415V, 50Hz
Cooling Capacity (Btu/h)3,62,0003,82,0003,99,0004,20,000
Cooling Capacity (kW)106.0112.0117.0123.0
Heating Capacity (Btu/h)4,06,0004,30,0004,47,0004,71,000
Heating Capacity (kW)119.0126.0131.0138.0
Capacity Control (%)4-1003-1004-1003-100
Casing ColourIvory White (5Y7.5/1)
Compressor TypeHermetically Sealed Scroll Type
No. of Compressor2+21+1+2
Airflow Rate (m³/min)257+297297+297191+191+257191+191+297
Machine Weight (kg)285+305305+305195+195+285200+200+325
Sound Level (dBA)66686567
Operation Range – Cooling (°CDB)-5 ~ 49
Operation Range – Heating (°CDB)-20 ~ 15.5
Refrigerant TypeR410A
Refrigerant Charge (kg)11.8+11.87.6+7.6+11.8
Liquid Pipe (mm)ø19.1
Gas Pipe (mm)ø41.3

Note

Specifications are based on the following conditions:

1. Cooling – Indoor temp. 27°CDB, 19°CWB, Outdoor temp. 35°CDB, Equivalent piping length 7.5m, Level difference 0m.

2. Heating – Indoor temp. 20°CDB, Outdoor temp. 7°CDB, 6°CWB, Equivalent piping length 7.5m, Level difference 0m.

3. Sound level – Anechoic chamber conversion value, measured at a point 1m in front of the unit at a height of 1.5m; during actual operation these values are normally somewhat higher as a result of ambient conditions.

Specification — Heat Pump: RXYQ46ARY6/48ARY6/50ARY6/52ARY6/54ARY6/56ARY6/58ARY6/60ARY6

ModelRXYQ46ARY6RXYQ48ARY6RXYQ50ARY6RXYQ52ARY6RXYQ54ARY6RXYQ56ARY6RXYQ58ARY6RXYQ60ARY6
Power Supply3-Phase, 380-415V, 50Hz
Cooling Capacity (Btu/h)4,44,0004,61,0004,78,0004,95,0005,12,0005,32,0005,53,0005,73,000
Cooling Capacity (kW)130135140145.0150.0156.0162.0168
Heating Capacity (Btu/h)4,95,0005,12,0005,32,0005,53,0005,73,0005,97,0006,21,0006,45,000
Heating Capacity (kW)145150156162.0168.0175.0182.0189
Capacity Control (%)3-1002-100
Casing ColourIvory White (5Y7.5/1)
Compressor TypeHermetically Sealed Scroll Type
No. of Compressor2+2+2
Machine Weight (kg)195+195+305265+265+265265+265+285265+285+285285+285+285285+285+305285+305+305305+305+305
Sound Level (dBA)6566686970
Operation Range – Cooling (°CDB)-5 ~ 49
Operation Range – Heating (°CDB)-20 ~ 15.5
Refrigerant TypeR410A
Refrigerant Charge (kg)9.1+9.3+9.39.3+9.3+9.39.3+9.3+11.89.3+11.8+11.811.8+11.8+11.8
Liquid Pipe (mm)ø19.1
Gas Pipe (mm)ø41.3

Note

Specifications are based on the following conditions:

1. Cooling – Indoor temp. 27°CDB, 19°CWB, Outdoor temp. 35°CDB, Equivalent piping length 7.5m, Level difference 0m.

2. Heating – Indoor temp. 20°CDB, Outdoor temp. 7°CDB, 6°CWB, Equivalent piping length 7.5m, Level difference 0m.

3. Sound level – Anechoic chamber conversion value, measured at a point 1m in front of the unit at a height of 1.5m; during actual operation these values are normally somewhat higher as a result of ambient conditions.